DSpace
 

EPrints@IIT Delhi >
Faculty Research Publicatons  >
Chemistry >

Please use this identifier to cite or link to this item: http://eprint.iitd.ac.in/handle/2074/590

Full metadata record

DC FieldValueLanguage
dc.contributor.authorPancras, J Patrick-
dc.contributor.authorPuri, Bal Krishan-
dc.contributor.authorTaher, Mohammad Ali-
dc.contributor.authorDehzoei, Ali Mostafavi-
dc.contributor.authorSheibani, Ali-
dc.date.accessioned2005-07-28T06:44:44Z-
dc.date.available2005-07-28T06:44:44Z-
dc.date.issued1998-
dc.identifier.citationTalanta, 46(4), 1107–1113en
dc.identifier.urihttp://eprint.iitd.ac.in/dspace/handle/2074/590-
dc.description.abstractCobalt-2-(5-bromo-2-pyridylazo)-5- iethylaminophenol (5-Br-PADAP)- etraphenylborate ion associated complex is quantitatively adsorbed on microcrystalline naphthalene in the pH range 3.5–9.5 from a fairly large volume of the aqueous samples (preconcentration factor -30). After filtration, the solid mass consisting of the cobalt complex and naphthalene was dissolved with 5 ml of dimethylformamide (DMF) and the metal determined by first-derivative spectrophotometry. The cobalt-5-Br-PADAP complex can alternatively be quantitatively retained on ammonium tetraphenylborate-naphthalene adsorbent filled in a column (preconcentration factor 120) in the same pH range and determined similarly. The detection limit is 30 ppb (signal-to-noise ratio=2) and the calibration curve is linear over 0.3–8.0 mg of cobalt in 5 ml of the final DMF solution. Eight replicate determinations of 1.0 mg of cobalt gave a mean peak height of 0.208 (at 611.5 nm) with a relative standard deviation of 1.2%. The sensitivity of the method is 1.04 (dA:dnm) ml mg-1 found from the slope of the calibration curve. The interference of a large number of anions and cations on the determination of cobalt has been studied and the optimized conditions developed were utilized for its trace determination in various standard alloys and biological samples.en
dc.format.extent205214 bytes-
dc.format.mimetypeapplication/pdf-
dc.language.isoenen
dc.subjectCobalt determinationen
dc.subjectDerivative spectrophotometryen
dc.subject5-Br-PADAPen
dc.subjectTPBen
dc.subjectNaphthaleneen
dc.subjectStandard alloysen
dc.subjectBiological samplesen
dc.titlePreconcentration of trace cobalt with the ion pair of 2-(5-bromo-2 paridylazo)-5-diethylaminophenol and tetraphenylborate onto microcrystallin naphthalene column method and its determination by derivative spectrophotometryen
dc.typeArticleen
Appears in Collections:Chemistry

Files in This Item:

File Description SizeFormat
pancraspre1998.pdf200.4 kBAdobe PDFView/Open
View Statistics

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

 

Valid XHTML 1.0! DSpace Software Copyright © 2002-2010  Duraspace - Feedback