DSpace
 

EPrints@IIT Delhi >
Faculty Research Publicatons  >
Biomedical Engineering [CBME] >

Please use this identifier to cite or link to this item: http://eprint.iitd.ac.in/handle/2074/617

Full metadata record

DC FieldValueLanguage
dc.contributor.authorBiswas, Subrata-
dc.contributor.authorGuha, Sujoy K-
dc.date.accessioned2005-07-30T07:11:08Z-
dc.date.available2005-07-30T07:11:08Z-
dc.date.issued1999-
dc.identifier.citationBioelectrochemistry and Bioenergetics, 48(2), 431–434en
dc.identifier.urihttp://eprint.iitd.ac.in/dspace/handle/2074/617-
dc.description.abstractThe creation of surface modified human term placental amnion by electrofusing human cells onto its surface has been thought of. A multiple-pulse electrofusion protocol with 10 square pulses of 10-ms pulse length, and electric field of 0.2 kV cmy1, can make erythrocyte–amnion tissue electrofusion possible. The protocol devised merge the cell-tissue-adherence steps with fusogenic pulse. The finding opens up a new avenue of cell electrofusion onto human tissue with minimal procedural complexities.en
dc.format.extent618540 bytes-
dc.format.mimetypeapplication/pdf-
dc.language.isoenen
dc.subjectMicrovillien
dc.subjectPlacental amnionen
dc.subjectCell-tissue electrofusionen
dc.subjectGraft tissueen
dc.titleMultiple-pulse-mediated electrofusion of intact erythrocyte onto human term placental amnionen
dc.typeArticleen
Appears in Collections:Biomedical Engineering [CBME]

Files in This Item:

File Description SizeFormat
biswasmul1999.pdf604.04 kBAdobe PDFView/Open
View Statistics

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

 

Valid XHTML 1.0! DSpace Software Copyright © 2002-2010  Duraspace - Feedback