DC FieldValueLanguage
dc.contributor.authorBhadoria, B S-
dc.contributor.authorChandra, A-
dc.date.accessioned2005-08-12T08:54:16Z-
dc.date.available2005-08-12T08:54:16Z-
dc.date.issued1999-
dc.identifier.citationEnergy Conversion & Management, 40(18), 1985-1995en
dc.identifier.urihttp://eprint.iitd.ac.in/dspace/handle/2074/743-
dc.description.abstractLosses in an MHD generator not only reduce the power output but also degrade it. The losses due to heat, friction and leakage through insulating-wall/slag have been analyzed for the diagonal generator for better control and performance. The losses due to leakage are higher than the heat and friction losses.The effect of wall temperature on losses is significant. The heat and friction losses decrease with increase in wall temperature, whereas the leakage losses increase with increase in wall temperature. The slag losses reduce power output from the channel drastically.en
dc.format.extent208928 bytes-
dc.format.mimetypeapplication/pdf-
dc.language.isoenen
dc.subjectMHD power generationen
dc.subjectCoal combustionen
dc.subjectLossesen
dc.subjectSlagen
dc.subjectLeakageen
dc.titleLosses in diagonal MHD generatoren
dc.typeArticleen
Appears in Collections:Energy Studies [CES]

Files in This Item:

File Description SizeFormat
bhadonalos1999.pdf204.03 kBAdobe PDFView/Open
View Statistics

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

 

Valid XHTML 1.0! DSpace Software Copyright © 2002-2010  Duraspace - Feedback