|
EPrints@IIT Delhi >
Faculty Research Publicatons >
Civil Engineering >
Please use this identifier to cite or link to this item:
http://hdl.handle.net/2074/881
|
| Title: | Response of light equipment on torsional building with passive tuned mass damper |
| Authors: | Agrawal, Abhijit K |
| Keywords: | Vibration control Tuned mass dumper Non-classical damping Torsional coupling Primary and secondary systems |
| Issue Date: | 2000 |
| Citation: | Computers and Structures, 78(4), 591-602 |
| Abstract: | Response behavior of an equipment system attached to a linear and torsionally coupled primary system is studied under random ground excitation idealized as broad band stationary random process, represented by white noise. A passive tuned mass damper (TMD) is attached to the equipment system to attenuate its peak responses. The response quantities of interest are relative displacement between the equipment system and the primary system, and absolute
acceleration of the equipment system itself. The responses of the equipment system are evaluated under a number of
important parametric variations. The variance of response quantities of interest of the equipment system are obtained
by frequency domain spectral analysis. The results of the study indicate that attachment of the TMD with the equipment system and torsional coupling of the primary system significantly affect the response behavior of the equipment system. |
| URI: | http://eprint.iitd.ac.in/dspace/handle/2074/881 |
| Appears in Collections: | Civil Engineering
|
Files in This Item:
| File |
Description |
Size | Format |
| agarwalres2000.pdf | | 366Kb | Adobe PDF | View/Open |
|
Show full item record
All items in DSpace are protected by copyright, with all rights reserved.
|