DSpace
 

EPrints@IIT Delhi >
Faculty Research Publicatons  >
Chemistry >

Please use this identifier to cite or link to this item: http://eprint.iitd.ac.in/handle/2074/892

Full metadata record

DC FieldValueLanguage
dc.contributor.authorTewari, Pankaj Kumar-
dc.contributor.authorSingh, Ajai Kumar-
dc.date.accessioned2005-10-18T05:12:33Z-
dc.date.available2005-10-18T05:12:33Z-
dc.date.issued2001-
dc.identifier.citationTalanta, 53(4), 823–833en
dc.identifier.urihttp://eprint.iitd.ac.in/dspace/handle/2074/892-
dc.description.abstractA new chelating resin is prepared by coupling Amberlite XAD-2 with pyrocatechol through an azo spacer, characterized (by elemental analysis, IR and TGA) and studied for preconcentrating Cd(II), Co(II), Cu(II), Fe(III), Ni(II) and Zn(II) using flame atomic absorption spectrometry (FAAS) for metal monitoring. The sorption is quantitative in the pH range 3.0–6.5, whereas quantitative desorption occurs instantaneously with 2 M HCl or HNO3 The sorption capacity has been found to be in the range 0.023–0.092 mmol g-1 of resin. The loading half time (t1:2) is 1.4, 4.8, 1.6, 3.2, 2.3 and 1.8 min, respectively for Cd, Co, Cu, Fe, Ni and Zn. The tolerance limits of electrolytes NaCl, NaBr, NaNO3, Na2SO4 and Na3PO4 in the sorption of all the six metal ions (0.2 mg ml-1) are reported. The Mg(II) and Ca(II) are tolerable with each of them (0.2 mg ml-1) up to a concentration level of 0.01–1.0 M. The enrichment factor has been found to be 200 except for Fe and Cu for which the values are 80 and 100, respectively. The lowest concentration of metal ion for quantitative recovery is 5, 10, 20, 25, 10 and 10 mg l-1 for Cd, Co, Cu, Fe, Ni and Zn, respectively. The simultaneous determination of all these metal ions is possible and the method has been applied to determine all the six metal ions in tap and river water samples (RSD53.9 and 7.3%, respectively).The cobalt content of pharmaceutical vitamin tablets is estimated by FAAS (RSD-2%) after its preconcentration with the present chelating resin.en
dc.format.extent286176 bytes-
dc.format.mimetypeapplication/pdf-
dc.language.isoenen
dc.subjectAmberlite XAD-2en
dc.subjectAtomic absorption spectrometryen
dc.subjectChelating resinen
dc.subjectExtractionen
dc.subjectMetal ionsen
dc.subjectPyrocatecholen
dc.subjectWater analysisen
dc.titleSynthesis, characterization and applications of pyrocatechol modified amberlite XAD-2 resin for preconcentration and determination of metal ions in water samples by flame atomic absorption spectrometry (FAAS)en
dc.typeArticleen
Appears in Collections:Chemistry

Files in This Item:

File Description SizeFormat
tiwarisyn2001.pdf279.47 kBAdobe PDFView/Open
View Statistics

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

 

Valid XHTML 1.0! DSpace Software Copyright © 2002-2010  Duraspace - Feedback