Author: | Choudhury, C; Chauhan, P M; Garg, H P |
Advisor: | Advisor |
Date: | 1995
|
Publisher: | |
Citation: | Solar Ener
|
Series/Report no.: |
|
Item Type: | Article
|
Keywords: | optimization of design; operational parameters; thermal energy; cross-sectional area; air mass velocity; void fraction |
Abstract: | This study deals with the optimization of design and operational parameters of a rock bed
thermal energy storage device coupled to a two pass single cover solar air heater, i.e., charging time $ rock bed size (flow length, H), and cross-sectional area for square cross section (AR), rock size (DR), air mass velocity per unit bed cross-sectional area (G), and void fraction (6). The optimization has been accomplished by investigating the effects of the above parameters on the total energy stored and the cost
per unit energy stored in the rock bed for the winter climatic conditions of Delhi. |