Search
Now showing items 1-10 of 46
Performance analysis of adaptive fuzzy logic controller for switched reluctance motor drive system
(1998)
This paper presents the application of an adaptive fuzzy algorithm for the speed control of a switched reluctance motor (SRM). The SRM is a highly nonlinear control plant and operates in saturation to maximize the torque ...
Analysis of switched reluctance motor drive under fault conditions
(1998)
The paper presents a comprehensive analysis of a switched reluctance motor (SRM) drive system under different realistic fault conditions. A simple modeling and simulation technique is used to investigate the fault tolerant ...
A universal active power filter for single-phase reactive power and harmonic compensation
(1998)
In modern power distribution systems, the majority of loads draw reactive power and/or harmonic currents from the AC source along with main active power currents. These nonunity power factor linear and nonlinear loads cause ...
Power factor correction and load balancing in three-phase distribution systems
(1998)
This paper deals with the different methods for compensating unbalanced three phase loads. Compensation of grounded, ungrounded star connected and delta connected three phase unbalanced load has been carried out. Three ...
Comparison of PI, VSC and energy balance controller for single phase active filter control
(1998)
This paper presents a comparison among proportional-integral, variable structure voltage controller and energy balance controller for the control of single phase active filter. Proportional-integral (PI) and variable ...
An improved converter with power factor correction of 3-phase auxiliary loads
(1998)
This paper deals with the performance analysis of an improved converter which is capable of supplying reactive power of other 3-phase linear loads at the common point of connection to the AC mains. The converter with ...
Active power filter with sliding mode control
(1997)
The paper presents an active power filter (APF) to eliminate harmonics and to compensate reactive power and neutral current of three-phase four-wire symmetrical and unbalanced nonlinear loads. A set of three single-phase ...
Variable structure control of four pole voltage source inverter for active filtering of nonlinear loads in 3-phase 4-wire systems
(1998)
This paper presents the analysis of four leg voltage source inverter (VSI) used as an active filter (AF) for reactive power compensation, load balancing, harmonic elimination and neutral current compensation in three-phase ...
Design and implementation of a new control algorithm for a three-phase active filter
(1997)
This paper presents a new control scheme for a voltage source active filter (AF) which compensates, simultaneously, the harmonics and reactive power of nonlinear loads. The reference compensating currents are estimated ...
Selection of capacitors for the self regulated short shunt self excited induction generator
(1994)
The self regulating feature of a self-excited induction generator (SEIG) by connecting additional capacitors is examined. A system consisting of both shunt and series capacitors has been analyzed. A methodology has been ...